The context
Data Centres must achieve the highest levels of availability
As major power consumers data centres must optimise their power demand
Human error remains the cause of most power failures
Integration challenges
Facilitate hardware selection & installation
Reduce footprint
Project cost optimisation
On-time delivery of the project
Operation challenges
Maximise power availability
Capacity planning
Optimise energy usage
Achieve Tier certification
Simplify and optimise maintenance
Anticipate potential risks
Our solutions
Every step of the way
Innovation is at the heart of our solutions. We aim to answer your needs at each step of your project.
Schematic
Critical power path <160kVA - UPS in 1N configuration - Entreprise
Image
Schematic
Critical power path <600kVA - UPS in 2N configuration - Entreprise / Colocation
Image
Schematic
Critical power path >600kVA UPS in catcher configuration using static switching
Image
Schematic
Generic for design
Image
Schematic
Generic for maintenance
Image
Design
1
Modular fault tolerant power without compromise
- Flexibility to increase the power output live
- High efficiency eco-mode operation
- Ultimate supply redundancy
- Minimal MTTR with a spare power module on-site
2
Monolithic unrivalled power performance
- Embedded digital technology
- Optimised maintenance by design
- Extended and flexible backup time
3
Li-Ion battery for high power density
- Control Li-Ion battery to ensure system availability
- Prevent any danger with an adequate battery management system
- Interact with UPS for overall system reliability and availability
4
Modular fault tolerant power without compromise
- Flexibility to increase the power output live
- High efficiency eco-mode operation
- Ultimate supply redundancy
- Minimal MTTR with a spare power module on-site
5
Monolithic unrivalled power performance
- Embedded digital technology
- Optimised maintenance by design
- Extended and flexible backup time
6
Maximise power availability with static switches
- Rack mounted STS for single corded critical loads
- Option with bypass available for easy maintenance
7
Ultimate modularity for the critical environments
- Flexibility to increase the power output live
- High efficiency eco-mode operation
- Ultimate supply redundancy
- Minimal MTTR with a spare power module on-site
8
Monolithic unrivalled power performance
- Embedded digital technology
- Optimised maintenance by design
- Extended and flexible backup time
9
Li-Ion battery for high power density
- Control Li-Ion battery to ensure system availability
- Prevent any danger with an adequate battery management system
- Interact with UPS for overall system reliability and availability
10
Maximise power availability with static switches
- Avoid propagating faults to alternate supply
- Redundant power supplies and controllers for high reliability
- Ultimate supply redundancy
Select
The challenge:
- Optimise the architecture for high levels of reliability
- Switching transformers downstream of static transfer switch in some cases
- Select the right UPS considering short circuit currents and maintainability
1
UPS selector (<120kVA)
Determine the optimum UPS
- Enter your installation parameters and see the recommended UPS
- Access technical data
2
Experts in static transfer switching
- IEC and UL static transfer switch options
- ATSM downstream transformer management function to avoid surges
Maintain
The challenge: maximum availability
Optimise the performance of the equipment supplying continuous power to your critical loads throughout its life cycle. The majority of failures in data centres are caused by human error so use specialist original manufacturer maintenance teams and remote monitoring to ensure maximum availability.
1
SoLink remote monitoring – preventive maintenance
- Restore your systems in record time
- Improve future performance
2
Original manufacturer service contracts
- Specialist teams at your service
- Only use approved spare parts
- Fast response
3
Design for maintenance
- Modular UPS designs ensure fast module replacement
- Keeping a spare module on-site ensures availability
- Bypass on UPS and STS to allow no-break inspection & maintenance