Strong Points
Function
Compact tower UPS system saves space in the operating environment.
Prime
Trustworthy power
Reliable and cost effective protection to assure operational continuity.
Advantages
Robust and easy to install
- Quick and simple installation: no configuration necessary on first startup.
- Easy connections via IEC 320 sockets or terminals.
- Wide input voltage tolerance limits the switchovers to battery mode prolonging the battery life.
- Wide operating ambient temperature up to 45°C.
- Single and three-phase input with automatic configuration (8-10 kVA).
High protection and availability
- True online double conversion technology (VFI) assures high availability and total load protection.
- Compatible with different applications, operating environments and generator sets.
- Automatic bypass supplies the loads in the event of overloads or faults.
- Manual bypass for periodic or emergency maintenance.
- Standard Over Voltage Control Device (OVCD) protects the UPS and the load from dangerous mains peak-voltages.
Certified product
- Safety compliance certified by TÜV.
- Performance tested and verified by third independent laboratory.
Wide battery configurability
- Modular battery extension flexibility enables limitless autonomy configuration.
- Hot-swap modular battery extension increases back-up times even after installation according to the load criticality to be supplied.
- Modular battery extension enables models with integrated powerful battery charger ensure constant and reliable operation using external high capacity batteries, provide power supply continuity during long outages and assure a fast recharging.
Technical data
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Sn [kVA] | 1000VA | 2000VA | 3000VA | 6000VA | 10000VA | 8500VA | 10000VA |
Pn [kW] | 1000W | 2000W | 3000W | 6000W | 10000W | 8500W | 10000W |
Input /output | 1/1 | 1/1 or 3/1 |
Â
Input | |||||||
---|---|---|---|---|---|---|---|
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Rated voltage | 230V (1/1) 110÷300V; (160÷300V @100% load) |
230V (1/1) 110÷276V; (160÷276V @100% load) |
400V (3/1), 230V (1/1) 110÷276V; (160÷276V @100% load) |
||||
Rated frequency | 40-70Hz (50/60Hz +/-5% Auto-Selectable) | ||||||
Power factor | >0,99 |
Â
Output | |||||||
---|---|---|---|---|---|---|---|
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Rated voltage | 220/230/240V (±1%) | ||||||
Rated frequency | 50/60Hz (±0.1Hz in battery mode) | ||||||
Overload | up to 105% continuously; 125% x 3min; 150% x 30sec | up to 105% continuously; 125% x 10min; 150% x 30sec | |||||
Crest factor | 3:1 | ||||||
Connections | 4 x IEC 320 (C13) | 8 x IEC 320 (C13) | 8 x IEC 320 (C13) + 1 (C19) | terminals |
Â
Batteries | |||||||
---|---|---|---|---|---|---|---|
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Type | sealed lead-acid maintenance free - expected life 3/5 years | ||||||
Voltage | 36VDC | 72VDC | 192VDC | ||||
Back-up time(1)(2) (min) | 12 | 16 | 9 | 11 | 7 | 9 | 7 |
Battery charger(3) | 8A | 12A |
Â
Communication | |||||||
---|---|---|---|---|---|---|---|
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Interfaces | RS232 - USB - Dry contact | ||||||
Ethernet adapter | NET VISION (TCP/IP & SNMP) optional card | ||||||
Local communication software
|
Local View |
Â
Efficiency | |||||||
---|---|---|---|---|---|---|---|
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Online mode | up to 93% | up to 95% |
Â
Environment | |||||||
---|---|---|---|---|---|---|---|
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Ambient service temperature | from 0°C to +40°C (up to 45°C(4)) | ||||||
Relative humidity | <95% non-condensing | ||||||
Maximum altitude | 1000m without de-rating | ||||||
Noise level at 1m | <50dBA | <55dBA |
Â
UPS Cabinet | |||||||
---|---|---|---|---|---|---|---|
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Dimensions W x D x HÂ (mm) | 145 x 404 x 224 | 192 x 428 x 322 | 225 x 416 x 589 | ||||
Weight (models with internal batteries)Â (kg) | 14,4 | 26 | 53 | 61 | 58 | 61 | |
Weight (models without internal batteries)Â (kg) | 8 | 11 | 13,5 | 25,8 | - | ||
Degree of protection | IP20 |
Â
Standards | |||||||
---|---|---|---|---|---|---|---|
Model | ITY3-TW010B | ITY3-TW020B | ITY3-TW030B | ITY3-TW060B | ITY3-TW100B | ITY3-TW108B | ITY3-TW110B |
Safety | IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2 | ||||||
EMC | IEC/EN 62040-2, AS 62040.2 | ||||||
Performance | IEC/EN 62040-3 (efficiency tested by an external independent body) | ||||||
Product declaration | CE, RCM (E2376) |
Â
(1) @75% of rated load (models with internal batteries) PF 0.7
(2) Models with internal batteries
(3) Models without batteries
(4) Conditions apply
Communication
Software features
- 1 slot for communication options.
- USB port for UPS management based on HID protocol.
- MODBUS RTU (RS232).
- LOCAL VIEW software for local UPS monitoring and shutdown for Windows, Linux and MAC Osx.
- Clear and uncluttered LCD interface for easy UPS monitoring, even for less specialist users.
Communication options
- Dry-contact card.
- NET VISION: professional WEB/SNMP Ethernet interface for secure UPS monitoring and remote automatic shutdown.
- Environmental Monitoring Device (EMD).
- REMOTE VIEW PRO supervision software.