U3Ryb25nIFBvaW50cw==

  • UmVsaWFiaWxpdHkgYW5kIHBlcmZvcm1hbmNl

  • U2FmZXR5IG9mIHByb3BlcnR5IGFuZCBwZXJzb25uZWw=

  • U2ltcGxpY2l0eQ==

  • RWFzeSB0byBpbnN0YWxs

RnVuY3Rpb24=

U0lSQ08gQUMgYXJlIG1hbnVhbGx5IG9wZXJhdGVkIG11bHRpcG9sYXIgbG9hZCBicmVhayBzd2l0Y2hlcy48YnIgLz4NClRoZXkgbWFrZSBhbmQgYnJlYWsgdW5kZXIgbG9hZCBjb25kaXRpb25zIGFuZCBwcm92aWRlIHNhZmV0eSBpc29sYXRpb24uPGJyIC8+DQpTSVJDTyBBQyBhcmUgZGVzaWduZWQgZm9yIGhhcnNoIGFwcGxpY2F0aW9ucyB1cCB0byAxMDAwIFZBQyAtIEFDIDIz

Technical Characteristics

Height [mm] 235
Width [mm] 230
Depth [mm] 160
Weight [kg] 4.55
Control operator Direct : B2, J1 / External : S2
Number of poles 3
Rated voltage 690 VAC
Rated current [A] 400
Type Front operation
Frame size B5

Classification

UNSPSC 39122233
ETIM Class EC000216
IGCC 5290

Commerce

Description Manually operated Load break switch SIRCO AC frame B5 with 3 poles, 400A, 690 VAC frontal direct operation with handle type J1 or frontal external operation with handle type S2. Delivered without handle
Effective date 2012-07-03
Offer Life Cycle Code 40
Country of origin FR

Environmental Sustainability

Climate change - Total - Cradle to Grave [kg CO₂ eq.] 237
Climate change - Total - Cradle to Gate [kg CO₂ eq.] 27
SVHC > 0.1 mass percentage? No
RoHS applicable? Yes

ETIM - Electrical characteristics

Max. rated operation voltage Ue AC [V] 690
Rated operating voltage [V] 400..690
Rated permanent current Iu [A] 400
Rated permanent current at AC-23, 400 V [A] 400
Rated permanent current at AC-21, 400 V [A] 400
Rated short-time withstand current lcw [kA] 11
Rated operation power at AC-23, 400 V [kW] 220
Switching power at 400 V [kW] 220
Conditioned rated short-circuit current Iq [kA] 50
Number of poles 3

ETIM - Mechanical characteristics

Suitable for floor mounting No
Suitable for front mounting 4-hole No
Suitable for front mounting centre No
Suitable for distribution board installation No
Suitable for intermediate mounting Yes
Colour control element Other
Degree of protection (IP), front side IP20
Width [mm] 230
Height [mm] 235
Depth [mm] 160

ETIM - Technical features

Version as main switch Yes
Version as maintenance-/service switch Yes
Version as safety switch Yes
Version as emergency stop installation Yes
Version as reversing switch No
Number of switches 1
Motor drive optional No
Motor drive integrated No
Voltage release optional No
Device construction Built-in device fixed built-in technique
Type of control element Other
Interlockable Yes
Type of electrical connection of main circuit Bolt connection

Logistics

GTIN/EAN 3596032774448
Customs number 8536508000
Price unit PC
Weight of the packing unit [kg] 4.55
Length of the packing unit [m] 0.15
Width of the packing unit [m] 0.26
Depth of the packing unit [m] 0.29

Norms

Conformity to standards IEC
  • PDF
    SIRCO, SIRCO CD & SIRCO AC Range_UE declaration
    Select
  • PDF
    SIRCO AC 200-2000A_SIRCO 125A-4000A_BUREAU VERITAS certificate
    Select
  • PDF
    SIRCO AC 3&4p 125A to 2500A
    Select
  • PDF
    SIRCO - Load break switches for power distribution
    Select
  • SIRCO AC 3X400A F 690Vac CAD 26AC3040
  • PDF
    SIRCO AC & SIRCO Range_UK declaration
    Select
  • PDF
    Load break switches
    Select

References

SIRCO AC is also available in 25 versions

Item Type Rated current [A] Number of poles Frame size Control operator Rated voltage Select
26AC3020 Front operation 200 3 B4a Direct : B2, J1 / External : S2 690 VAC
26AC4020 Front operation 200 4 B4a Direct : B2, J1 / External : S2 690 VAC
26AC3025 Front operation 250 3 B4a Direct : B2, J1 / External : S2 690 VAC
26AC4025 Front operation 250 4 B4a Direct : B2, J1 / External : S2 690 VAC
26AC3031 Front operation 315 3 B4b Direct : B2, J1 / External : S2 690 VAC
26AC4031 Front operation 315 4 B4b Direct : B2, J1 / External : S2 690 VAC
26AC4040 Front operation 400 4 B5 Direct : B2, J1 / External : S2 690 VAC
26AC3050 Front operation 500 3 B5 Direct : B2, J1 / External : S2 690 VAC
26AC4050 Front operation 500 4 B5 Direct : B2, J1 / External : S2 690 VAC
26AC3063 Front operation 630 3 B6 Direct : C2 / External : S4 690 VAC
26AC3064 Front operation 630 3 B6 Direct : C2 / External : S4 690 VAC
26AC4063 Front operation 630 4 B6 Direct : C2 / External : S4 690 VAC
26AC4064 Front operation 630 4 B6 Direct : C2 / External : S4 690 VAC
26AC3080 Front operation 800 3 B6 Direct : C2 / External : S4 690 VAC
26AC4080 Front operation 800 4 B6 Direct : C2 / External : S4 690 VAC
26AC3100 Front operation 1000 3 B6 Direct : C2 / External : S4 690 VAC
26AC4100 Front operation 1000 4 B6 Direct : C2 / External : S4 690 VAC
26AC3120 Front operation 1250 3 B6 Direct : C2 / External : S4 690 VAC
26AC3121 Front operation 1250 3 B7 Direct : C2 / External : S4 690 VAC
26AC4120 Front operation 1250 4 B6 Direct : C2 / External : S4 690 VAC
26AC4121 Front operation 1250 4 B7 Direct : C2 / External : S4 690 VAC
26AC3160 Front operation 1600 3 B7 Direct : C2 / External : S4 690 VAC
26AC4160 Front operation 1600 4 B7 Direct : C2 / External : S4 690 VAC
26AC3200 Front operation 2000 3 B8 Direct : S5 / External : S5 690 VAC