Strong Points
Function
STATYS Cabinet is an intelligent static transfer system (STS) that provides increased supply availability, automatically transferring its loads to alternative power sources when the primary source falls out of set values.
STATYS Cabinet offers the highest protection against main power source outages, failure in the upstream power distribution system, malfunctions due to defective devices, or operator errors.
Conformity to standards
IEC 62310 – 1
IEC 62310 – 2
IEC 60529
CE
UKCA
References
STATYS Cabinet is available in X versions
Advantages
Best resiliency for optimal power availability
STATYS Cabinet is designed to ensure the best power availability by eliminating all traditional single points of failure thanks to:
- Dual redundant electronic power supply (4x).
- Micro controller redundancy, including history log and settings physically separated for additional safety.
- SCR driver integrates both independent and redundant power supplies, incorporating SCR fault sensing.
- An "auto-hold" function included to guarantee power continuity, even if an internal problem occurs.
- Cooling redundancy with fan failure monitoring.
- Segragation of main functions to prevent internal fault propagation.
Advanced Transformer Switching Management (ATSM)
ATSM is an embedded transfer method developed by Socomec to manage downstream magnetic loads such as transformers present in PDU.
This function protects current occurring after source transfer on a magnetic load.
By specifically managing, the phases sequence ATSM protects the installation from high transient overvoltages causing protection tripping linked to load transfer.
Designed to fit your installation
STATYS Cabinet offers the opportunity to implement a redundant architecture ensuring availability while providing more site flexibility:
- Compliant with all distribution architecture including Catcher.
- Available in 3 or 4-wire arrangement with or without neutral.
- Flexible digital control capacity that can adapt to any operational or electrical environment conditions.
- Capability to manage synchronised and non-synchronised sources according to load specificity.
- Non-linear loads compatibility.
35 years of innovation driven by the field
A firmware based on thousands of units installed and millions of operating hours to achieve the best level of availability:
- Source independance.
- Short circuit detection.
- ATSM integrated as a standard feature.
- Worldwide coverage of products and services.